Hydraulic conductivity of soil is measured as 2×10-2  cm/sec…

Hydraulic conductivity of soil is measured as 2×10-2  cm/sec.  After an accident, a truck carrying dissolved salt solution releases its contents to surface.  The distance between the spill and a groundwater well is 1600 meter.  The groundwater elevation at the spill location is 5.5 meter and well location is 5.3 meters. Porosity of soil is 0.4.  Travel time of contaminant to the well is most nearly (years):

100 mL of a solution with a TOC (total organic carbon) conce…

100 mL of a solution with a TOC (total organic carbon) concentration of 0.5% is placed in each of the five containers with activated carbon and shaken for 48 hours. The samples are filtered and the concentration of TOC measured, yielding the following analyses: Test beaker no.:          1          2          3          4          5 Carbon (grams):          10        8          6          4          2 TOC (mg/L):               42        53        85        129      267   The Freundlich isotherm is to be used:  X/M = k Cf 1/n The value of X (TOC removed) in the 1st beaker is (mg):

100 mL of a solution with a TOC (total organic carbon) conce…

100 mL of a solution with a TOC (total organic carbon) concentration of 0.5% is placed in each of the five containers with activated carbon and shaken for 48 hours. The samples are filtered and the concentration of TOC measured, yielding the following analyses: Test beaker no.:          1          2          3          4          5 Carbon (grams):          10        8          6          4          2 TOC (mg/L):               42        53        85        129      267   The Freundlich isotherm is to be used:  X/M = k Cf 1/n The value of X (TOC removed) in the 1st beaker is (mg):

The following data have been collected during the trial burn…

The following data have been collected during the trial burn studies for incineration of a waste mixture.  The principle hazardous constituent (POHC) for the waste has been determined as dioxin.   Compound                  inlet flow rate (lb/hr)              outlet flow rate (lb/hr) Benzene                      1200                                                    4 Toluene                       800                                                      3 Dioxin                         30                                                        1 Destruction removal efficiency for the POHC is:

The following data have been collected during the trial burn…

The following data have been collected during the trial burn studies for incineration of a waste mixture.  The principle hazardous constituent (POHC) for the waste has been determined as dioxin.   Compound                  inlet flow rate (lb/hr)              outlet flow rate (lb/hr) Benzene                      1200                                                    4 Toluene                       800                                                      3 Dioxin                         30                                                        1 Destruction removal efficiency for the POHC is:

Air stripping process is used as a pump and treat method for…

Air stripping process is used as a pump and treat method for removing a trichloroethylene (TCE) from groundwater.  The following conditions apply: Influent flow rate = 40 m3/sec QA/QW = 20 Dimensionless Henry’s constant = 0.2 TCE concentration in the influent = 1.1 mg/L TCE concentration in the effluent = 50 µg/L The stripping factor is most nearly:

Carbon adsorption experiments have been conducted.  Plot of:…

Carbon adsorption experiments have been conducted.  Plot of:  ln(X/M) vs ln(Ce) to determine the Freundlich constants a and b in the Freundlich equation (written as:  X/M = a Cf b ) provided the following linear equation: Y = 0.351 X + 2.131 Data collected correspond to which of the following Freundlich equation: