A patient who is currently in the ER as a code STEMI displays the following 12 lead. An infarction of this vessel should be expected:
Author: Anonymous
There are 3 commonly used types of embolic protection device…
There are 3 commonly used types of embolic protection devices. The below are of the most common used. Which is #2?
No reflow is a complication of rotational athrectomy believe…
No reflow is a complication of rotational athrectomy believed due to:
From the patient data below calculate the MV area and index:…
From the patient data below calculate the MV area and index: Fick CO= 5.5 L/min Flow= 121 ml/sec Mean gradient= 15 mmHg BSA= 1.7 M²
How much should the ACT before a coronary intervention?
How much should the ACT before a coronary intervention?
According to Poiseuille’s law if the length of a catheter is…
According to Poiseuille’s law if the length of a catheter is doubled, how much should the injection pressure be increased to get the same flow?
What indicator provides the best estimate of risk of radiati…
What indicator provides the best estimate of risk of radiation skin injury?
The best way to reduce patient motion and heart motion artif…
The best way to reduce patient motion and heart motion artifact in Cine imaging is:
Calculate the Fick CO from the data given below: VO2= 200ml/…
Calculate the Fick CO from the data given below: VO2= 200ml/min Hgb= 15 gm/dl AO blood= 20 vol% PA blood= 15 vol%
Excessive bleeding around the sheath can be prevented or con…
Excessive bleeding around the sheath can be prevented or controlled by: